EtherNet/IP to Modbus TCP Linking Device

Minimize costs when connecting Modbus-TCP networks/devices to ControlLogix® or CompactLogix® controllers with an EtherNet/IP interface.


FAST COPYING I/O DATA (BIG DATA SUPPORT)

The Linking Device primary function is with the fast transfer of large I/O data between the two networks. This offloads your Logix PLC from working with additional calculations. The Linking Device acts as a slave (adapter) on EtherNet/IP and as a powerful client (master), on the Modbus-TCP network, handling up to 8 KB of I/O data. The data transmission between the two networks is completely transparent.


SEAMLESS INTEGRATION WITH STUDIO 5000

With its unique Studio 5000® Logix designer integration, everything is accessible from within Studio 5000, including Modbus-TCP network configuration. No extra 3rd-party software or licenses needed.


CONNECT, CONFIGURE, DONE

EtherNet/IP Linking Devices are configured using a Custom Add-On Profile for Studio 5000 Logix Designer which dynamically generates data structures based on the configuration. No ladder logic files (add on instructions) needed.

Furthermore, it also supports automatic generation of named and structured Studio 5000 controller tags, which eliminates the need to create alias tags.

Память
Поддержка SD карт YES, enabling easy module replacement
Коммуникационные интерфейсы
Интерфейсы EtherNet/IP to Modbus-TCP Linking Device
Modbus-TCP address  Any valid IP address can be used
Поддержка EtherNet/IP: 10/100 Mbit/s autodetect
Управляемый: Any valid IP address can be used
Поддержка Modbus TCP: 10/100 Mbit/s autodetect
Конструктив
Назначение Шлюз EtherNet/IP
Серия Linking Devices
Степень защиты корпуса: IP20, NEMA rating 1
Вид монтажа: Vertical
Возможности монтажа DIN-rail (EN 50022 standard) or Wall mount
Температура хранения -40 to +85 ℃ or -40 to +185°F
Температура эксплуатации: -25 to +70 ℃ or -13 to +158°F
Вес, кг. 160 g, 0,35 lb
Габариты, мм 110 x 35 x 101mm or 4,33 x 1,38x 3,98"
Гарантия от производителя 3 years
Комплект поставки HMS-EN2MB-R Linking Device, Installation guide,(Power supply not included)
Сертификаты ODVA, CE,CULUS (ATEX/Haz.Loc - PENDING)
Порты
Портов EtherNet/IP 2x RJ45
Портов Modbus TCP 2x RJ45
Питание
Входное напряжение питания DC: 24 VDC +/- 20%

Написать отзыв

Ваше имя:


Ваш отзыв: Примечание: HTML разметка не поддерживается! Используйте обычный текст.

Оценка: Плохо           Хорошо

Введите код, указанный на картинке:



Описание

EtherNet/IP to Modbus TCP Linking Device

Minimize costs when connecting Modbus-TCP networks/devices to ControlLogix® or CompactLogix® controllers with an EtherNet/IP interface.


FAST COPYING I/O DATA (BIG DATA SUPPORT)

The Linking Device primary function is with the fast transfer of large I/O data between the two networks. This offloads your Logix PLC from working with additional calculations. The Linking Device acts as a slave (adapter) on EtherNet/IP and as a powerful client (master), on the Modbus-TCP network, handling up to 8 KB of I/O data. The data transmission between the two networks is completely transparent.


SEAMLESS INTEGRATION WITH STUDIO 5000

With its unique Studio 5000® Logix designer integration, everything is accessible from within Studio 5000, including Modbus-TCP network configuration. No extra 3rd-party software or licenses needed.


CONNECT, CONFIGURE, DONE

EtherNet/IP Linking Devices are configured using a Custom Add-On Profile for Studio 5000 Logix Designer which dynamically generates data structures based on the configuration. No ladder logic files (add on instructions) needed.

Furthermore, it also supports automatic generation of named and structured Studio 5000 controller tags, which eliminates the need to create alias tags.

Характеристики

Память
Поддержка SD карт YES, enabling easy module replacement
Коммуникационные интерфейсы
Интерфейсы EtherNet/IP to Modbus-TCP Linking Device
Modbus-TCP address  Any valid IP address can be used
Поддержка EtherNet/IP: 10/100 Mbit/s autodetect
Управляемый: Any valid IP address can be used
Поддержка Modbus TCP: 10/100 Mbit/s autodetect
Конструктив
Назначение Шлюз EtherNet/IP
Серия Linking Devices
Степень защиты корпуса: IP20, NEMA rating 1
Вид монтажа: Vertical
Возможности монтажа DIN-rail (EN 50022 standard) or Wall mount
Температура хранения -40 to +85 ℃ or -40 to +185°F
Температура эксплуатации: -25 to +70 ℃ or -13 to +158°F
Вес, кг. 160 g, 0,35 lb
Габариты, мм 110 x 35 x 101mm or 4,33 x 1,38x 3,98"
Гарантия от производителя 3 years
Комплект поставки HMS-EN2MB-R Linking Device, Installation guide,(Power supply not included)
Сертификаты ODVA, CE,CULUS (ATEX/Haz.Loc - PENDING)
Порты
Портов EtherNet/IP 2x RJ45
Портов Modbus TCP 2x RJ45
Питание
Входное напряжение питания DC: 24 VDC +/- 20%