The Anybus X-gateway allows you to seamlessly inter-connect/extend PLC control systems and their connected devices on a Modbus RTU network.
FAST COPYING OF I/O DATAThe X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave on both sides of the Modbus RTU network and provides a simple network extension. The data transmission between the two networks is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
Коммуникационные интерфейсы | |
Интерфейсы | Modbus-RTU Slave-Modbus-RTU Slave |
Управляемый: | via USB port withAnybus Configuration Manager software |
Конструктив | |
Назначение | Шлюз Modbus-RTU Slave |
Серия | X-gateway |
Степень защиты корпуса: | IP20, NEMA rating 1 |
Конструкция корпуса: | Aluminium and plastic |
Вид монтажа: | Vertical / Flat* |
Гальваническая изоляция | YES, on both BUS/Ethernet side |
Возможности монтажа | DIN-rail (EN 50022 standard) |
Температура хранения | -40 to +85 ℃ or -40 to +185°F |
Температура эксплуатации: | -25 to +65 ℃ or -13 to +149°F |
Вес, кг. | 400g or 0,880 lbs |
Габариты, мм | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Гарантия от производителя | 3 years |
Дополнительные аксессуары | *Extra wide DIN-clip for flat mounting(Order Code SP1784) |
Комплект поставки | Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. For bulk pack orders, all configuration software can be downloaded under "files anddocumentation" from this website. (Power supply not included) |
Сертификаты | CE,CULUS, ATEX/Haz.Loc, RoHS |
Питание | |
Входное напряжение питания DC: | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Ток потребления: | max. 400mA (Typical 200mA) |
The Anybus X-gateway allows you to seamlessly inter-connect/extend PLC control systems and their connected devices on a Modbus RTU network.
FAST COPYING OF I/O DATAThe X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave on both sides of the Modbus RTU network and provides a simple network extension. The data transmission between the two networks is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
Коммуникационные интерфейсы | |
Интерфейсы | Modbus-RTU Slave-Modbus-RTU Slave |
Управляемый: | via USB port withAnybus Configuration Manager software |
Конструктив | |
Назначение | Шлюз Modbus-RTU Slave |
Серия | X-gateway |
Степень защиты корпуса: | IP20, NEMA rating 1 |
Конструкция корпуса: | Aluminium and plastic |
Вид монтажа: | Vertical / Flat* |
Гальваническая изоляция | YES, on both BUS/Ethernet side |
Возможности монтажа | DIN-rail (EN 50022 standard) |
Температура хранения | -40 to +85 ℃ or -40 to +185°F |
Температура эксплуатации: | -25 to +65 ℃ or -13 to +149°F |
Вес, кг. | 400g or 0,880 lbs |
Габариты, мм | 114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Гарантия от производителя | 3 years |
Дополнительные аксессуары | *Extra wide DIN-clip for flat mounting(Order Code SP1784) |
Комплект поставки | Resource CD, USB configuration cable, Quick start guide, manuals. Anybus Configuration Manager software. For bulk pack orders, all configuration software can be downloaded under "files anddocumentation" from this website. (Power supply not included) |
Сертификаты | CE,CULUS, ATEX/Haz.Loc, RoHS |
Питание | |
Входное напряжение питания DC: | 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Ток потребления: | max. 400mA (Typical 200mA) |